SASY 60i Busbar SystemTable of ContentsSASY 60i Busbar SystemBusbar supportsPage xx60 mm SystemPage xxD-Type Fuse-BasesPage xxBusbar-Slide Switch-Disconnector-FusesPage xxNH-Fuse-Switch-DisconnectorsPage xxDimensionsPage xxUL/CSA approvals listPage xxCopper weight, extra chargesPage xx1

SASY 60i Busbar SystemTechnical Data on Busbar SupportsBBS-3/FL(-NA)General InformationStandards and regulationsFitting positionTightening torque of covertype-tested according to VDE 0660 Part 500IEC/EN 60439-1Nmvertical, horizontal4 f-extinguishing according to UL 94-VORAL 7035RAL 7035CTI 200CTI 200120 C120 IuIuIuIuIuAAAAAAAAAA C nsFlammabilityColourComparative tracking indexUninterrupted duty temperatureCurrent PathsRated insulation voltageRated operational voltageRated frequencyCentre line distance of busbarsRated uninterrupted current 1)with busbar 12 x 5 mmwith busbar 15 x 5 mmwith busbar 20 x 5 mmwith busbar 25 x 5 mmwith busbar 30 x 5 mmwith busbar 12 x 10 mmwith busbar 20 x 10 mmwith busbar 30 x 10 mmwith 500 mm2with 720 mm2Ambient temperatureTemperature of busbarRated peak withstand current 2)with busbar 12 x 5 mmwith busbar 15 x 5 mmwith busbar 20 x 5 mmwith busbar 25 x 5 mmwith busbar 30 x 5 mmwith busbar 12 x 10 mmwith busbar 20 x 10 mmwith busbar 30 x 10 mmwith 500 mm2with 720 mm2Short-circuit timeSupport centre line distance1)2)BBS-3/PRvertical, horizontal4In case of temperature variances, DIN 43671 requires a kA correction factor to be taken into account.For other support centre line distances, please refer to the short-circuit strength diagrams.Short-circuit strength diagrams according to IEC/EN 60439-1 for 60 mm SASY 60i Busbar SystemsBBS-3/PRBBS-3/FL Values measured during type-testing107162 Values measured during type-testingPeak current Ipk (kA)Peak current Ipk (kA)107066Support centre line distance (mm)Support centre line distance (mm)2

SASY 60i Busbar SystemShort-circuit strength diagrams according to UL 845 for 60 mm SASY 60i Busbar SystemsBBS-3/PRBBS-3/FL-NA Values measured during type-testing107162 Values measured during type-testingPeak current Ir.m.s. (RMS) in kAPeak current Ir.m.s. (RMS) in kA107067Support centre line distance (mm)Support centre line distance (mm)Rated constant current Iu in ACurrent load TT 500 mm2Ambient temperature CBusbar temperature Ts in CRated constant current Iu in ACurrent load TT 720 mm2Ambient temperature CBusbar temperature Ts in C3

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemConductor connectionsThe ratios between conductor cross-sections in mm2 and AWG/MCM-sizes are listed below:1.5 mm216 AWG2.5 mm214 AWG4 mm212 AWG6 mm210 AWG10 mm28 AWG16 mm26 AWG25 mm24 AWG35 mm22 AWG50 mm20 AWG70 mm22/0 AWG95 mm23/0 AWG120 mm2250 MCM150 mm2300 MCM185 mm2350 MCM240 mm2500 MCM300 mm2600 MCMBusbar supports60 mm system according to IEC1-pole for busbars 12x5 – 30x10, double-T-bars2-pole for busbars 12x5 – 30x103-pole for busbars 12x5 – 30x10 and 12/20/ 30 x 5/103-pole for double-T-barsTighten screws for fixing the cover and bottom of the support at a torque of 4 Nm min.60 mm system according to UL3-pole for busbars 12/20/ 30 x 5/103-pole for double-T-barsTighten screws for fixing the cover and bottom of the support at a torque of 4 Nm min.Silicone-free, chlorine-freeTemperature resistant up to 120 CSelf-extinguishing according to UL 94Comparative tracking index CTI 200Busbars according to DIN EN 13601Tin-plated Cu-bars significantly reduce the work necessary for preparing the contact points.Cu-busbars are effectively protected against aggressive n500 mm2720 mm2Permissible tolerances:Radius R 0.3 0.7Width: 0.1 / – 0.5Thickness: 0.1 / – 0.1Center line distance: 0.5 mm (60 mm system)Variance on the contacting level: 0.4 mmAmpacity with copper barsCross-sections of barsmmSurfacemm212 x 520 x 530 x 512 x 1020 x 1030 x 10Double-TDouble-T60100150120200300500720Ampacity according to IEC35 C ambient temperature65 C bar temperatureA20032045036052063095012004Ampacity according to UL/CSAA2003204503605206309501200

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemBusbars according to DIN EN 13601For busbar applications that have not been type-tested, UL508A allows an ampacity of 1000A/inch2 (1.55A/mm²) if no tests have beencarried out. This value may be higher if the product or the application has been tested accordingly. Moeller has conducted extensivetests for the user’s maximum benefit in using the SASY 60i busbar system. The advantage of such tests is that one can use the SASY60ibusbar system with higher rated currents than the default value allows. A busbar of size 30x10 mm for example can be charged with 630Ainstead of 465A only.Higher current carrying capacities to DIN 43671 were obtained under operating conditions.Busbar temperature is normally positively influenced by mounting components on the busbar and by air circulation within the installation.Depending on the respective ambient temperature, you can calculate the correction factor k2 according to DIN 43 671 for flat busbars. Ifambient conditions change, a correction factor needs to be taken into account.On the other hand, increased loads may occur if the components feature a correspondingly high temperature resistance.A 30 x 10 tin-plated busbar can under normal conditions be loaded with 630 A . With a load of 800A, for instance, a k2 correction factor of1.3 is necessary. It follows from the diagram that with this factor and 35 C air temperature, the busbar heats up to approx. 85 C.Base plateSilicone-free, chlorine-freeTemperature resistant up to 110 CSelf-extinguishing according to UL 94Busbar coversfor busbars of 12 x 5, 12–30 x 5, 12–30 x 10Double-T-profilesSilicone-free, chlorine-freeTemperature resistant up to 110 CSelf-extinguishing according to UL 94Modular system coverto be attached to 60 mm systems, 3-poleto busbars of 12/20/30 x 5/10, 25 x 5,to double-T-profilesCover profileCover profileCover profilefronttop/bottomsupportSilicone-free, chlorine-freeTemperature resistant up to 120 CSelf-extinguishing according to UL 945

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemUniversal conductor terminalUsed for connecting conductors featuring cross-sections of 1.5–120 mm2 on busbars 5 or 10 mm thick.Integrated retaining springs, an open terminal space and captive terminal screws make the installation job easy.Suitableconductors 1)1.5–16 mm2 Cu, , , **,8 x 6 x 0.54–35 mm2 Cu, , , **,3/ 6 x 9 x 0.816–70 mm2 Cu, , **,2x3 / 6 x 9 x 0.8, 6 x 13 x 0.516–120 mm2 Cu, , **,4 /6/ 10 x 16 x 0.8Current carrying capacity of contact point*180 ATerminal space WxHmm7.5 x 7.5270 A10.5 x 11400 A14 x 14440 A17 x 15Busbars WxHmm x5 x 10 x5 x 10 x5 x 10, TT x5 x 10, 0AKU120/5AKU120/10* Current carrying capacities specified reflect the thermal capacities of the contact points under favourable conditions (with a maximumof conductors that can be connected). They do not, however, invalidate the validity of conductor cross-sections and of current carryingcapacities required by any national and international regulations.** A reduction of maximum conductor cross-sections might be necessary.Brace terminalsFor connecting round conductors of 95–300 mm2 and multi-layer copper bars.The gripper-type of termination technology allows to embrace both sides of the busbar and to connect the conductor without drilling.Suitableconductors 1)95–185 mm2 Cu, Al***, ,150–300 mm2 Cu, Al***, ,3 x 20 x 1 to 10 x 32 x 1,(2x) 50 x 10Current carrying capacity of contact point *500 ATerminal space WxHmm–600 A–800 A32 x 251600 A55 x 28*** Connections to aluminium conductors are not maintenance-free1)Round conductor, single-wiredRound conductor, fine-wired with expertly pressed wire end ferruleRound conductor, multi-wiredSector conductor, single-wiredSector conductor, multi-wiredCu-BandCu-Bar6Busbars WxHmm20x5 - 30x10TT20x5 - 30x10TT20x5 - 30x10TT20x5 - 30x10TTTypeAKS185AKS300AKS-CU-BANDAKS1000

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemConnecting terminal platesIncl. cover cap16, 50, 120 mm23-pole, 690 V Centre line distance of bars 60 mmBusbars x 5 – 10,Double-T-profilesTerminal plates:Silicone-free, chlorine-freeTemperature resistant up to 120 CSelf-extinguishing according to UL 94Comparative tracking index CTI 200Cover cap:Silicone-free, chlorine-freeTemperature resistant up to 120 CSelf-extinguishing according to UL 94Suitableconductors 1)1,5 –16 mm2 Cu,,**,6 –50 (70) mm2 Cu, , **,6 x 9x 0.835 –120 mm2 Cu, , **,6 / 10 x 16 x 0.8Current carrying capacity of contact point *80 ATerminal space WxHmm–300 A10 x 15440 A15 x 15Current carrying capacity of contact point *560 ATerminal space WxHmm800 A32 x 251600 A55 x 28Busbars WxHmm x 5 – 10TT x 5 – 10TT x 5 – 10TTTypeBusbars WxHmm20x5 - 30x10TT20x5 - 30x10TypeBBA-TP3/16BBA-TP3/50BBA-TP3/120Connecting set, 3-poleIncl.cover capSuitableconductors120–300 mm2 Cu, Al***,, , ,3 x 20 x 1 to 10 x 32 x 1TP3/CUBAND,(2x) 50 x 10** It might be necessary to reduce maximum conductor cross-sections.*** Connections to aluminium conductors are not maintenance-free.1)Round conductors, single-wiredRound conductors, fine-wired with expertly pressed wire end ferrulesRound conductors, multi-wiredSector conductors, single-wiredSector conductors, multi-wiredCu-BandCu-Bar7TT20x5 - 30x10TTBBA-TP3/300BBA-AKS1000

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemBusbar connecting terminalFor lenghtwise connection of identically shaped busbars without drillingCurrent carrying capacity of contact point630 A630 A630 A1600 A1600 AOverall lengthmm1509515050150Permissible misalignment of bars1 mm5 mm5 mm2 mm5 mmSpacing betweensystems in mm100 - 11050 - 60100 - 1109 -20100 - 110Terminal space W x H(without spacers)41 x 20 – 4251 x 20 – 00/720-150Profile terminals for double-T-barsCurrent carrying capacity of contact point1600 A1600 AProfileTTTTAKP800AKP1000Use spacers provided when two multi-layer CU-BAND types of copper busbars are connected in parallel.xStart busbar adapter3-pole, 690 V Can be used on all busbars in a 60 mm system.Thanks to the combi-base it is suitable for a thickness of both 5 and 10 mm.DIN EN 60715 support rail, plastic, can be adjusted on a 1.25-mm grid.Copper conductors are ultrasound welded.Base body:Silicone-free, chlorine-freeTemperature resistant up to 120 CSelf-extinguishing according to UL 94Comparative tracking index CTI 200Support rails:Silicone-free, chlorine-freeTemperature resistant up to 100 CPVC conductor insulation:Temperature resistant up to 105 COverall length of the connecting cables:BBA0-25, BBA0-32, BBA0R-25, BBA0R-32, BBA0-25/2TS, BBA0/2TS-L : 93 mmBBA0C-16, BBA0RC-16: 125 mmBBA4-63, BBA2-63, BBA4L-63, BBA2L-63: 115 mmShort circuit current ratings SCCR:PKZM0-0,16 to PKZM0-10: 50 kAPKZM0-12, -16:50 kAPKZM0-20, -25, -32:18 kADirect and reverse motor starters (PKZM0 DILM 1) or MSC BBA up to 32 A on busbar adapters and busbar systemSASY 60i1) anytype of connection between PKZM and DILM8

SASY 60i Busbar SystemTechnical Data on the 60 mm SystemBusbar adapter NZMParameterDesignBar systemBar contactingConnection of the switchgearShort Circuit Current Ratings SCCRNZM1-XAD1603-pole, 690 V 60 mmcombi-basetop35 kA at 480 VNZM2-XAD2503-pole, 690 V 60 mmclaw-type terminaltop or bottom65 kA at 480 V50 kA at 600 VNZM3-XAD6303-pole, 690 V 60 mmclaw-type terminaltop or bottom65 kA at 480 V50 kA at 600 VNZM1-XAD160Base body:ThermoplastTemperature resistant up to 120 CSelf-extinguishing according to UL 94Comparative tracking index CTI 200Halogen-freeConductor insulation:PVC,Temperature resistant up to 105 CNZM2-XAD250Base body:ThermoplastTemperature resistant up to 120 C,Self-extinguishing according to UL 94,Comparative tracking index CTI 200,Halogen-freeNZM3-XAD630Base body:ThermoplastTemperature resistant up to 120 C,Self-extinguishing according to UL 94,Comparative tracking index CTI 200,Halogen-freeDerating:Ambient temperature [ C]20Permissible rated current [A]630Derating to 630 ePlease observe the de-rating coefficients listed in the table above to determine the maximum ampacity allowed at different ambienttemperatures!ExampleAn NZM3.3-.630. device with an NZM3-XAD630 device adapter should be operated at an ambient temperature of 50 C.QuestionWhat is the maximum rated operating current Ie allowed Ie ? SolutionAt an ambient temperature of 50 C, the de-rating coefficient is 0.88. This means that Ie 630A x 0,88 544A.Der Schalter darf also bei 50 C, the device can therefore be operated at a maximum of Ie 544 A.9705040,80

SASY 60i Busbar SystemD-Type Slide Fuse-Base Design according to IEC/EN 60269-1, VDE 0636 Part 301 Vertical and horizontal mounting possible Delivered empty, without screw capsTechnical DataElectricalNumber of polesRated operational voltage UeRated frequencyRated operational current IeConv. thermal current with fuse-links IthRated dutyRated conditional short-circuit currentOvervoltage categoryRated impulse withstand voltage UimpPower loss per current pathPower loss of base without fuse-linksMax. permissible power loss of -PS)DIII-SO/63/3-R(-PS)3400 V AC40-60 Hz63 A63 Auninterrupted duty50 kAr.m.s.IV6 kV0.5 W1.5 W5.5 W3500 V AC40-60 Hz25 A25 Auninterrupted duty50 kAr.m.s.III4 kV0.4 W1.2 W4W3690 V AC40-60 Hz63 A63 Auninterrupted duty50 kAr.m.s.III4 kV3.34 W10 W7WMechanicalDevice heightWidthWeightMounting onto busbars, without drilling or screwing201 mm200 mm200 mm27 mm45 mm54 mm150 g140 g150 25x5/1025x5/1025x5/1030x5/1030x5/1030x5/10Degree of protection while operatingIP20IP20IP20TerminalsLift terminalsLift terminalsLift terminalsTerminal capacity1.5-35 mm21.5-25 mm21.5-25 mm2Tightening torque of terminal screws3-4 Nm2.6 Nm2.6 NmElectrical thread typeE18E27E33Ambient temperature range-25 to 55 C-25 to 55 C *)-25 to 55 C *)*) (35 C normal temperature, at 55 C with reduced operating current)Pollution degree333Climatic resistance: moist heatconstant acc. to IEC 60068-2-78, cyclical acc. to IEC 60068-2-30Busbar-Slide Switch Disconnector with Fuses D02-S/63/3-RS Design according to IEC/EN 60947-3Vertical and horizontal mounting possibleSupplied empty, without screw capsCurrent coding by means of cartridge-ring adapter insertSuitable for fuse-linksD01: 2, 4, 6, 10, 16 A in combination with cartridge-ring adapter insertsZ-D02-D01/PE-. and adapter spring Z-D02/SIKA-HFD02: 20, 25, 35, 50, 63 A Can be sealed with leadConnection diagramTechnical DataElectricalNumber of polesRated operational voltage UeACRated operational current IeConv. thermal currentwith fuse-links IthRated dutyRated conditional short-circuit currentUtilization categoryOvervoltage categoryRated impulse withstand voltage UimpPower loss per current pathPower loss per current pathwith fuse-linkMax. permissible power lossof fuse-links3P400 V / 40-60 Hz63 A63 AUninterrupted duty50 kAr.m.s.AC 23 BIII8 kV0.5 W with IeMechanicalDevice heightWidthWeightMounting onto busbars,without drilling or screwingDegree of protection while operatingTerminalsTerminal capacityTightening torqueof terminal screwsElectrical thread typeTemperature rangePollution degree7.5 W with Ie5.5 W10212 mm36 mm260 g20x5/10 mm30x5/10 mmIP30Lift terminals1.5-25 mm2 Cumax. 2.6 NmE18-25 to 55 C3

SASY 60i Busbar SystemBusbar-Slide Switch-Disconnector-Fuse D02-LTS/63/3-R Design according to IEC/EN 60947-3Vertical and horizontal mounting possibleSupplied emptyCurrent coding by means of cartridge-ring adapter insertSuitable for fuse-linksD01: 2, 4, 6, 10, 16 A in combination with cartridge-ring adapter insertsZ-D02-D01/PE-. and adapter spring Z-D02-LTS-HFD02: 20, 25, 35, 50, 63 ACylindrical 10x38: 1 - 32 A Can be sealed with leads, lockableConnection diagramD02-LTS/63/3-RD02-LTS/63/3-R-HKTechnical DataElectricalNumber of polesRated operational voltage UeACRated operational current IeRated uninterrupted current IuRated dutyRated short-circuit capacity Icm, IcnUtilization categoryOvervoltage categoryRated impulse withstand voltage UimpPower loss per current pathPower loss per current pathwith fuse-linkMax. permissible power lossof fuse-linksAuxiliary switch electrical1 COMax. thermal back-up fuse3P400 V / 40-60 Hz63 A63 AUninterrupted duty50 kAr.m.s.AC 22 BIV6 kV1.5 W with Ie7 W with Ie5.5 W5 A / 250 V AC2 A gLPLSM-B4/.-HS / CLS6-B4/.-HSMechanicalDevice heightWidthWeightMounting onto busbars,without drilling or screwingDegree of protection while operating(built-in)TerminalsTerminal capacityTightening torqueof terminal screwsTemperature rangePollution degreeConnectionFemal push-on connector11226 mm27 mm340 g12x5/10 mm15x5/10 mm20x5/10 mm25x5/10 mm30x5/10 mmIP20/IP40Lift terminals1.5-35 mm2 Cumax. 4 Nm-25 to 55 C32.8 x 0.5 mm

SASY 60i Busbar SystemNH-Fuse-Switch-Disconnector Mounting height max. 2000 mConnection diagramBreak-proof, flexible connection chamber3PFully insulated, shock hazard protected in acc. with IEC/EN 60947 or BGV A3The base body is made of glass fibre reinforced, high-temperature resistant,self-extinguishing and halogen-free plasticThe contact system consists of separately spring-loaded silver-plated coppercontactsThe switch cover is made of glass fibre reinforced, self-extinguishing, silicone and chlorine-free thermoplastThe switch cover features large viewing windows allowing to read the labelling and to see the flat indicator of the NH-fuse-linksThe viewing windows provide test holesVertical and horizontal mounting position is possibleDelivery without NH-fuse-linksElectricalTechnical data according toRated operational voltageRated operational voltageRated operational currentRated frequencyRated conditional short-circuit current ACRated conditional short-circuit current DCUtilization category AC 22 BRated making capacityRated breaking capacityUtilization category DC 21 BRated making capacityRated breaking capacityService life electrical - operating cyclesService life mechanical - operating cyclesPower loss with Ith AC, without NH-SEPower loss with Ith DC, without NH-SERated insulation voltageOvervoltage categoryRated impulse withstand voltageMax. Fuse-linkSizeMax. rated current gL/gGMax. permissible power loss of NH-SEUeUeIeUiGST00-160. GST1.GST2.GST3.V ACV DCAHzkAr.m.s.kAr.m.s.IEC/EN 60947-350022010040 - 605025500 / 690220 / 440160 / 10040 - 605025500 / 690220 / 440250 / 20040 - 605025500 / 690220 / 440400 / 31540 - 605025500 / 690220 / 440630 / 50040 - 605025AA300300480 / 300480 / 300750 / 600750 / 6001200 / 945 1890 / 15001200 / 945 1890 / 1500AA400400300170011.57.7500III815015030017006.9 / 2.74.6 / 1.8750III8300300200140012.9 / 8.38.6 / 5.5750III847547520080027 / 16.718 / 11.2750III875075020080052 / 32.834.7 / 63048WWV ACUimp kVPvMechanicalBusbar mountingAWmmTightening torqueAmbient temperature rangeDegree of protection (open front cover)Pollution degreeWeightClimatic resistance: moist heatCross sections of connectionsFlat connection (F)ScrewCable lugFlat busbarTightening torqueClamp-type terminal (S) / Lift terminal (K)Stranded CuCu-BandNo. of layersx widthx thicknessTightening torquePrism terminalStranded Al/CuTightening torqueDouble-prism terminalStranded Al/CuTightening torque1) Standard-connectionLTS-100/C00/3-RNm 1030x5/1030x5/1030x5/1030x5/10–4666-25 to 55-25 to 55-25 to 55 -25 to 55 -25 to 55IP20 (IP10)IP20 (IP10)IP20 (IP10) IP20 (IP10) IP20 (IP10)333330.570.934.45.36.6constant according to IEC 60068-2-78, cyclical according to IEC 60068-2-30mm2mmK1)1.5 - 506 x 9 x 0.8K1)1,5 - 706 x 9 x 0.8F1)M101 x 25-15030 x 1030 - 35S25 - 1506 x 16 x 0.8Nm2.62.69.52323mm2Nm70 - 1504.5120 - 24011120 - n the delivery condition12F1)M101 x 25-24030 x 1030 - 35S25 - 24010 x 16 x 0.8F1)M101 x 25-30030 x 1030 - 35S25 - 30011 x 21 x 1

SASY 60i Busbar SystemSwitch Cover with Fuse Monitoring for NH-Fuse-Switch-Disconnector GST. Operation indicationIn working order – 1 green LEDFuse blown – 3 red LEDs L1, L2, L3 Working current principle VDE-requirements regarding touch voltage ( 1000 Ohm/V) are compliedwith.To release, turn off the upstream main switch! Not applicable for single phase applicationConnection diagramTechnical dataElectricalTechnical data according toRated voltage UeVoltage rangeRated frequencyConsumptionRated insulation voltage UiOvervoltage categoryRated impulse withstand voltage UimpRelay contactsTechnical data according toRated voltageRated current IthMax. making currentUtilization categoryRated operational voltage UeRated operational current IeMinimum switching loadMax. switching capacityAC 1250 V AC 15250 V AC 3Endurance electrical comp.Maximum back-up fuseMechanicalTerminalsTerminal capacitystrandedTightening torqueof terminal screwsEndurance mechanical comp.Response/Release timeDepree of protectionTemperature rangePollution degreeIEC/EN 60255,VDE 0435 Part 3033 x 400 V AC - 690 V AC0,9 . 1,1xUe50-60 Hz1.5 VA (L2/L3)690 VIII6 kV1 NC, 1 NOEN 60204, EN 50178,VDE 0106250 V AC8 A DC15 AAC 15DC13230VAC 24VAC 24VDC 220VDC1A4A1A0,5 A5 V AC/DC, 300 mW, 5 mA2000 VA400 VA300 W80 x 103 operating cycles AC 14 A gL/gG / PLSM-B4.-HSFunctional diagram13Lift terminals0.25 - 1.5 mm20.5 - 0.6 Nm 10 x 106 operating cycles 500 msIP20-10 to 55 C3

SASY 60i Busbar SystemNH-Vertical Fuse-Switch-Disconnector NH-SLS, 3-pole Supplied without NH-fuse-linksCan be installed both in a vertical and horizontal positionSymmetrical device - top or bottom connection is possibleBreak-proof, flexible connection chamberFully insulated, shock hazard protected in accordance with IEC/EN 60947 orBGV A3The base body is made of glass fibre reinforced, high-temperature resistant, self-extinguishing and halogen-free plasticThe contact system consists of separately spring-loaded silver-plated copper contactsThe switch cover is made of glass fibre reinforced, self-extinguishing, silicone and chlorine-free thermoplastThe switch cover features large viewing windows allowing to read thelabelling and to see the flat indicator of the NH-fuse-linksThe viewing windows provide self-closing test holesThe switch cover can be deposited (“park position”)Connection diagramRemote resetwithout bridge:memory functionwith bridge:without memory functionFunctional diagramElectronic Fuse Monitoring Operation indicationFuse in working order – 1 green LEDFuse blown, cover open – 1 red LED Working current principle, alternatively with memory function/remote reset Internal resistance of the measuring paths within the MOhm-range, VDErequirements regarding touch voltage ( 1000 Ohm/V) are complied with.To release, turn off the upstream main switch! When using feeder bars the lines connected to the fuse monitoring systemmust be changed as follows: L1 L1’, L2 L2’, L3 L3’Technical DataNH-SLS-00/160-60(-SI)ElectricalTechnical data according toSizeNumber of poles/phasesConventional free air thermal current Ithwith NH-fuse-linksMax. permissible power loss ofNH-fuse-linksUtilization category AC 23 BRated operational voltage UeRated operational current IeRated conditional short-circuit currentwith fuse-linksUtilization categories AC 22 B, AC 21 BRated operational voltage UeRated operational current IeRated conditional short-circuit currentwith fuse-linksRated insulation voltage UiOvervoltage categoryRated impulse withstand voltage UimpRated frequencyRated dutyPower loss without NH-fuse-linksIEC/EN 60947-3003160 A12 W400 V AC160 A50 kA690 V AC (400 V AC)160 A50 kA1000 V (400 V)III8 kV (4 kV)50-60 Hzuninterrupted duty *20 W at 160AMechanicalMounting onto busbar system without drilling or screwing12x5/10 mm20x5/10 mm25x5/10 mm30x5/10 mmStandard connection - screwM8Cable lugs - Cu-conductor according to rated currentsas detailed in IEC/EN 60947-11 x 70 mm2Flat busbars20x8 mmTightening torque12 NmStandard connection - clamp strap2 x M5Stranded Cu1.5 x 70 mm2Copper band: No. of layers x width x height 9 x 9 x 0.8 mmFlat busbars12x10 mmTightening torque3 NmAmbient temperature range-5 C to 40 CDegree of protectionIP30Pollution degree3Electronic Fuse MonitoringElectricalTechnical data according toRated voltage UeVoltage rangeRated frequencyConsumptionRated insulation voltage UiOvervoltage categoryRated impulse withstand voltage UimpIEC/EN 60255,VDE 0435 Part 3033 x 400 V AC0,8 . 1,1xUe50-60 Hz2 VA (L2/L3)400 VIII4 kVRelay contactsTechnical data according toRated voltageRated current IthUtilization categoryRated operational voltage UeRated operational current IeEndurance electrical comp.Maximum back-up fuse2 COEN 60947-5-1250 V AC4AAC 15230 V AC1A1.5 x 105 operating cycles4 A gL/gG / PLSM-B4.-HSMechanicalTerminalsTerminal capacitysolidstrandedTightening torqueof terminal screwsEndurance mechanical comp.Response/Release timeLift terminals2 x 2.5 mm22 x 1.5 mm20.8 Nm 108 operating cycles 500 ms* In case of uninterrupted duty of several devices placed side by side, please take account of the rated load factor detailed in VDE 0660Part 500 / EN 60439-1, Table 1.For sizes 00/1-3 the distance to grounded elements must be at least 50/100 mm at the top and 25/50 mm at the side.14

SASY 60i Busbar SystemTechnical Data on Line Supports BZSpan disdance lShort-circuit strength diagrams for Line Supports BZuninfluenced prospective short circuit current JK15

SASY 60i Busbar 2/FL16

SASY 60i Busbar RBBC-BT-NA17

SASY 60i Busbar /PRBBC-RCOV1BBC-CS2-F BBC-CS2-T/B BBC-MCS2BBC-CS48/PR18

SASY 60i Busbar TP3/50BBA-TP3/120BBA-TP3/30019

SASY 60i Busbar SystemDimensionsBBA-TP3/CU-BandNote:BBA-TP3/1000 consists of 3x AKS1000 and 1x BBC-CS1.AKS1000a (mm)80b (mm)72BBC-CS1c (mm)55dmin (mm)13a (mm)228dmax (mm)2820b (mm)194c (mm)214

SASY 60i Busbar SystemDimensionsAKS185AKS300AKS-CU-BANDAKP1000AKU 16/5AKU 35/521

SASY 60i Busbar SystemDimensionsAKU 70/5AKU 120/5AKU 16/10AKU 35/10AKU 70/10AKU 120/1022

SASY 60i Busbar CU12-20x5/10-15023

SASY 60i Busbar SystemDimensionsNZM1-XAD160NZM2-XAD25024

SASY 60i Busbar SystemDimensionsNZM3-XAD550NZM3-XAD630Point of screwing onfor NZM3 XKR13OAxis of rotation for connection down/above25

SASY 60i Busbar -60-ADD/6.26

SASY 60i Busbar SystemDimensionsD02-SO/63/3-R-27Z-D02/R/3-36, Z-D02/R/3-54Marking9 x 21Front plate supportFront plate supportZ-D02-S-AB-SETD.SO/./3-R(-PS)Covered busbar supportwith Set Z-D02-S-AB-SETTypeD02-S/63/3-RSADII-SO/25/3-R(-PS) 45DIII-SO/63/3-R(-PS) 54Front plate supportD02-LTS/63/3-R(-HK)27

SASY 60i Busbar TypeSGST00-160-40-60-AOU 405060GST-.-AO / 3510414515658668228TU122020-305-105-155-10

SASY 60i Busbar /160-60(-SI)Cut-out for front plate* NH-SLS-00/160-60-SI(with electronic fusemonitoring)m . . . . . Number of vertical fuse-switch-disconnectors29

NH-Fuse-Switch-Disconnectors Page xx Dimensions Page xx UL/CSA approvals list Page xx Copper weight, extra charges Page xx. 2 SASY 60i Busbar System Technical Data on Busbar Supports BBS-3/FL(-NA) BBS-3/PR General Information Standards and regulations type-tested according to VDE 0660 Part 500IEC/EN 60439-1